What do I have to consider for the flue?

Correct selection and sizing of the flue is very important for the efficient functioning of the heating system. The cross-sectional area of flue required depends on different factors such as the nominal heating rate and the effective height of the flue. We recommend obtaining a calculation from the flue manufacturer.

 

However, a rule of thumb is:

In new buildings the installation of a corrosion-resistant flue is absolutely essential. For renovation of an existing flue or chimney different systems are available from various manufacturers – please ask your heating engineer or contractor for further information.

 

nominal heating rating   cross-sectional area of the chimney

up to 34,000 BTU/hr

(10 kW)

 

5.5 inch

34,000 to 68,300 BTU/hr (10-20 kW)  

5.5 to 6.3 inch

68,300 to 102,500 BTU/hr (20-30 kW)  